Home
/ Services /
Dimensional
Service 02 /
08
●
Consult Lab · scope confirmation
✓
On-site service available
✓
Certificate with as-found / as-left data

CAPABILITY & RANGE
What we cover, to what uncertainty.
Accredited — within ISO/IEC 17025 scope
Traceable
Representative template data — replace with your accredited schedule
Outside Micrometer
External length
0–25 mm — illustrative
Not specified — laboratory confirmation required
Consult Lab
In-lab
—
Caliper
External length
0–300 mm — illustrative
Not specified — laboratory confirmation required
Consult Lab
Both
—
Gauge Block
Reference length
0.5–100 mm — illustrative
Not specified — laboratory confirmation required
Consult Lab
In-lab
—
Representative records · Demo data
STANDARDS & TRACEABILITY
Every reading traces back to SI units.
Each result is linked to national and international standards through an unbroken chain of comparisons, every link with a stated uncertainty. Your certificate records it.
✓
As-found / as-left readings
Before and after any adjustment, at every test point.
✓
Measurement uncertainty
Expanded uncertainty, k = 2, for each result.
✓
Reference standards used
With their own calibration status and traceability.
✓
Identification
Unique certificate number, instrument make, model and serial.
✓
Conditions
Temperature and humidity at the time of calibration.
TRACEABILITY CHAIN
L1
National / international standard
SI realisation at a national metrology institute
L2
Accredited reference standard
Our primary references, calibrated externally
L3
METRILAB laboratory
Working standards and reference instruments
L4
Your instrument
Certificate with stated uncertainty
ACCREDITATION SCOPE
For parameters marked Accredited, confirm coverage against the laboratory’s current accredited scope before booking. Traceable calibrations may fall outside that scope.
RELATED CASE STUDY
How an aerospace manufacturer cut calibration downtime without expanding its vendor list.
CHALLENGE
An illustrative test cell uses electrical meters, dimensional tools, pressure gauges and torque tools owned by different teams. The sample register lacks consistent identification and agreed measurement points.
RESULT
The illustrative deliverable is one reconciled equipment register with discipline-specific work scopes and a record-review checklist. This is a fictional planning example, not a documented customer result.
instruments in scope
complete calibration cycle
service delivery
Need Dimensional calibration for your equipment?
Send your equipment list and we’ll confirm range, accreditation, turnaround and service options.
INCLUDE IN YOUR REQUEST
01
Manufacturer, model and serial / asset ID
02
Parameters and ranges in use
03
Accredited or traceable
04
Due dates
05
In-lab or on-site
RESPONSE
[Response time]
CONTACT
[Set lab contact]