Home
/ Services /
Electrical
Service 01 /
08
Calibration for electrical test and measurement equipment — from handheld multimeters to precision reference standards.
●
Consult Lab · scope confirmation
✓
Typical turnaround · 3–5 business days
✓
On-site service available
✓
Certificate with as-found / as-left data

FIG. E-01 · DC voltage comparison against a reference calibrator
DC voltage
AC voltage
DC current
AC current
Resistance
Frequency
Capacitance
Inductance
SPECIFICATION
Electrical · Rev. A
Doc. ML-SPEC-01
3–5 business days
Expedited service on request
Accredited or traceable
Stated per parameter on every certificate
Available
Selected parameters and ranges
1 µV – 1,000 V · 1 µA – 1,000 A
As-found / as-left
Uncertainty (k=2) · standards used
Courier pickup · drop-off
Or calibrated in place at your site
INSTRUMENTS WE CALIBRATE
Recognise your equipment.
10 instrument types in
4 families.
Not listed? Send the model — we will confirm.

FIG. E-02 · Bench instruments, reference standards and records
Electrical taxonomy
01
Voltage & Current
Handheld to bench measurement of V and I.
Digital multimeters
DCV · ACV · DCI · ACI · Ω
Clamp meters
ACI · DCI · ACV
02
Resistance & Insulation
Safety and installation testing.
Insulation testers
MΩ · test voltage
Earth / ground testers
Ω · test current
03
Calibration Sources
Instruments that calibrate other instruments.
Electrical calibrators
V · I · Ω source
Process calibrators
mA · V · TC / RTD simulation
04
Power & Signal
Supplies, waveforms, components and acquisition.
Power supplies
Output V · I · regulation
Oscilloscopes
Bandwidth · timebase · amplitude
LCR meters
L · C · R · D / Q
Data acquisition systems
Channel V · TC · scan rate
CAPABILITY & RANGE
What we cover, to what uncertainty.
Accredited — within ISO/IEC 17025 scope
Traceable
Representative template data — replace with your accredited schedule
Digital Multimeter
DC voltage
0–1000 V — illustrative
Not specified — laboratory confirmation required
Consult Lab
Both
—
Digital Multimeter
DC current
0–10 A — illustrative
Not specified — laboratory confirmation required
Consult Lab
In-lab
—
Resistance Meter
Resistance
1–1e+08 Ω — illustrative
Not specified — laboratory confirmation required
Consult Lab
In-lab
—
Representative records · Demo data
SERVICE DELIVERY
In the lab, or on your floor.

FIG. E-03 · Loop calibration on installed instrumentation
Mode AIn-lab
Mode BOn-site
Capability
Full range, every listed parameter
Selected parameters and ranges
Environment
23 °C ± 1 °C controlled laboratory
Your facility · conditions recorded
Uncertainty
Lowest achievable
Stated on certificate · typically higher
Logistics
Courier pickup or drop-off
Scheduled visit · shutdown or weekend
Downtime
Instrument away 3–5 business days
Minimal — calibrated in place
Best for
Reference standards and bench instruments
Installed and production-critical equipment
On-site capability varies by parameter and range. Each row in the capability table states where it can be performed.
STANDARDS & TRACEABILITY
Every reading traces back to SI units.
Each result is linked to national and international standards through an unbroken chain of comparisons, every link with a stated uncertainty. Your certificate records it.
✓
As-found / as-left readings
Before and after any adjustment, at every test point.
✓
Measurement uncertainty
Expanded uncertainty, k = 2, for each result.
✓
Reference standards used
With their own calibration status and traceability.
✓
Identification
Unique certificate number, instrument make, model and serial.
✓
Conditions
Temperature and humidity at the time of calibration.
TRACEABILITY CHAIN
L1
National / international standard
SI realisation at a national metrology institute
L2
Accredited reference standard
Our primary references, calibrated externally
L3
METRILAB laboratory
Working standards and reference instruments
L4
Your instrument
Certificate with stated uncertainty
ACCREDITATION SCOPE
For parameters marked Accredited, confirm coverage against the laboratory’s current accredited scope before booking. Traceable calibrations may fall outside that scope.
PROCESS
From list to certificate.
Typical in-lab cycle · 3–5 business days
RELEVANT INDUSTRIES
Where Electrical calibration carries weight.
The instruments that matter in each sector, and the quality context they are audited against.
DMMs · process calibrators · power analyzers
AS9100 quality systems · NADCAP-audited processes
Electrical safety analyzers · DMMs · LCR meters
ISO 13485 · IEC 60601 test equipment
Oscilloscopes · power supplies · DAQ systems
Production test · ESD control programmes
Process calibrators · DMMs · insulation testers
IATF 16949 · EV high-voltage safety
Clamp meters · DMMs · earth testers
ISO 9001 · maintenance and safety testing
Insulation testers · earth testers · power analyzers
Site QA · high-voltage maintenance
FAQ
Questions from calibration coordinators.
Not covered here? Talk to the lab.
RELATED CASE STUDY
How an aerospace manufacturer cut calibration downtime without expanding its vendor list.
CHALLENGE
An illustrative test cell uses electrical meters, dimensional tools, pressure gauges and torque tools owned by different teams. The sample register lacks consistent identification and agreed measurement points.
RESULT
The illustrative deliverable is one reconciled equipment register with discipline-specific work scopes and a record-review checklist. This is a fictional planning example, not a documented customer result.
instruments in scope
complete calibration cycle
service delivery
Need Electrical calibration for your equipment?
Send your equipment list and we’ll confirm range, accreditation, turnaround and service options.
INCLUDE IN YOUR REQUEST
01
Manufacturer, model and serial / asset ID
02
Parameters and ranges in use
03
Accredited or traceable
04
Due dates
05
In-lab or on-site
RESPONSE
[Response time]
CONTACT
[Set lab contact]